Digitizing with 3D-Touch Probe
Function MP
No. Bit
A B C Input AE-6
Entry value
Number of oscillations in normal
direction
6210

0 to 65.535 [1/sec] 0
Lubrication of touch probe axis
displacement for lubrication at the end
of a line
6220 -

0.000 to 999.999 [mm] 0
time intervals for lubrication
6221 -

0 to 65 535 [min] 0
Feed rate in normal direction 6230

0 to 1 000 [mm/min] 0
Maximum deflection of the stylus 6240

0 to 10 [mm] 0
Output of M90 on NC blocks of
digitized data 6260

0 = no output
1 = output
0
Rounding of decimal places
(NC blocks) 6270

0 = output in 0.001 mm (1 µm)
1 = output in 0.01 mm (10 µm)
2 = output in 0.0001 mm (0.1 µm)
0
R H
1.0 TNC
415 B/425/426
Machine Parameters MP 6210 - MP 6270 03.01.95 5.2 45