Function MP
No. Bit
A B C Input AE-6
Entry value
Constant feed rate in corners 74
60
*

0 to 179.9999 [°] 10
Display mode and software limit
switches for rotary axis
74
70
*
I08 - -
0 = 0 to ± 359.999° (software limit switches are
not monitored)
1 = 0 to ± 99 999.9999 [°]
0
Datum in datum table 7475

0 = datum point is workpiece datum
1 = datum point is machine datum
0
Output of tool number or pocket
number
with TOOL CALL block 7480.0

0 to 6
0 = no output
1 = output of tool number only when tool number
changes (W262)
2 = output of tool number with every TOOL CALL
(W262)
3 = output of pocket number (W262) and tool
number (W264) only when tool number changes
4 = output of pocket number (W262) and tool
number (W264) with every TOOL CALL
5 = output of pocket number (W262) and tool
number (W264) only when tool number changes;
pocket table does not change.
6 = output of pocket number (W264) with every
TOOL CALL; pocket table does not change.
2
R H
1.0 TNC
415B/425
Machine Parameters MP 7460 - MP 7480.0 06.03.95 5.2 65