Function MP
No. Bit
A B C Input AE-6
Entry value
with TOOL-DEF blocks
(only if MP7260 > 0)
7480.1

0 = no output
1 = output of tool number only when tool number
changes (W262)
2 = output of tool number with every TOOL DEF
(W262)
3 = output of pocket number (W262) and tool
number (W264) only when tool number changes
4 = output of pocket number (W262) and tool
number (W264) with every TOOL DEF
2
Number of traverse ranges 7490

0 = 1 range, 3 datums
1 = 3 ranges, 3 datums
2 = 1 range, 1 datum
3 = 3 ranges, 1 datum
0
* accessible via code number 123
R H
1.0 TNC
415B/425
Machine Parameters MP 7480.1 - MP 7490 03.01.95 5.2 66